Factory-Built Fireplace Repair, Based in Hawthorne
Twenty-six jobs, from refractory panels to chase tops.
On a factory-built unit the label decides the parts. Most calls start with a fireplace inspection, then move to the listed repair it points to.
Chimney Sweep
Flue pipe and firebox cleaned with brush heads sized to the pipe, including the metal sections hidden inside a framed chase.
Chimney Inspection
NFPA 211 Level 1, 2 or 3 checks for metal and masonry chimneys, picked by the reason you are calling.
Chimney Repair
Chase tops, pipe sections, caps, crowns and flashing repaired with listed parts on metal systems and matched mortar on brick.
Fireplace Inspection
Metal fireboxes checked panel by panel: refractory, damper, doors, screen and the clearances printed in the maker's manual.
Fireplace Repair
Cracked refractory panels, warped grates, broken dampers and doors on prefab fireboxes replaced with parts the maker lists.
Chimney Level 2 Inspection
Video of the whole flue plus the attic and chase, booked for a sale, a quake, a chimney fire or a new appliance.
Chimney Cap Installation
Rain caps for metal flues and masonry chimneys, chosen by pipe make and size, with the old cap hauled away.
Chimney Flashing Repair
Water at the roof line stopped on framed chases and brick chimneys, once the real entry point is found.
Chimney Masonry Repair
Brick, mortar and crown repairs for the masonry chimneys on the older houses we also service.
Chimney Rebuilds
Rebuilding a framed chase, or the upper part of a brick chimney, when a repair would not hold.
Fireplace Cleaning
Ash, soot and grime removed from metal and brick fireboxes, with soft refractory panels and coated glass handled gently.
Gas Fireplace Cleaning
Burner, pilot, media and glass cleaned on direct-vent and B-vent gas units, plus the outdoor termination.
Gas Fireplace Repair
Pilots, thermopiles, valves, igniters and remotes on gas fireplaces traced with a meter and replaced with the maker's parts.
Fireplace Remodel
Surround, mantel and hearth changes on prefab fireplaces, kept inside the clearances the maker set.
Fireplace Inserts
Gas inserts for masonry openings, and the listed choices for prefab boxes whose manual does not allow one.
Pellet Stove Repair
Pellet stoves that will not light, feed or keep running, tested one part at a time with a meter.
Wood Stove Repair
Gaskets, baffles, firebrick, glass and stovepipe on freestanding and insert wood stoves, with parts for the model.
Gas Logs
Log sets for brick fireplaces and the approved log kits a prefab firebox allows, connected and leak tested.
Chimney Seismic Retrofit
Quake work for tall brick chimneys: anchoring to the house, roof bracing or a lighter top, chosen after a look.
Chimney Crown Repair
Cracked or crumbling crowns on brick chimneys sealed or recast; on a framed chase, the chase top does that job.
Dryer Vent Cleaning
Lint cleared from the duct between the dryer and the outside hood, with the run and its fittings checked.
Chimney Liner Installation
Stainless liners for brick flues, and replacement pipe for metal ones, each matched to the appliance it serves.
Chimney Leak Repair
Water traced through chase tops, siding, flashing, crowns and caps, then stopped where it actually enters.
Chimney Waterproofing
Breathable repellent for brick chimneys, applied once the joints and crown are in good repair.
Chimney Damper Repair
Seized blades, broken handles and rusted frames on prefab and masonry dampers, repaired with the right part.
Chimney Chase Cover
Rusted or dished chase tops replaced with stainless or coated covers made to the measured chase.

Wheeler, Hawthorne
Metal fireboxes, framed chases and the parts that keep them listed.
Owners of tract homes and condos with a factory-built fireplace.
Wheeler Chimney Pros works out of Hawthorne, and most of our calls come from tract homes, condos and townhomes where the fireplace is a metal box set into a framed wall.
Those units were built and tested as complete systems, so we treat them that way. Cracked panels, bent damper blades, rusted chase tops and worn caps are replaced with the parts the maker lists for that model, not with whatever fits.
When the label is gone or the model is no longer made, the report says so plainly and lays out what can still be done. Brick chimneys on older houses get masonry repair, by masonry rules.
Rating plate read before anything is quoted
Manual pulled for the exact model
Photos of panels, flue, chase top and cap
Parts and prices written down first
Why the Label Comes First
The model number decides which panels, doors, logs and caps belong in your fireplace.
So it is the first thing we look for when we kneel at the opening.
Listing Before Opinion
The maker's manual decides what goes into a factory-built fireplace. We read it before we recommend anything, and we quote parts it lists.
Plain Part Names
Refractory panel, chase top, termination, spacer. We name the part, show the photo and say what it does, so the report makes sense when you read it later.
Quotes in Writing
Every repair is written up with the part and the price before work starts. If a part is no longer made, the quote says so and lists the options.
Metal and Masonry Alike
Most of our days are spent on prefab units in tract homes and condos, and we service brick chimneys too, each repaired by its own rules.
Buyers, agents, managers and code fixes
Prefab or brick, a chimney report often lands mid-deal or mid-lease. Wheeler Chimney Pros keeps one page for each of the four situations behind those calls.
Home sale inspection
Buying in Hawthorne from out of town? The agents let us in, and the Level 2 report and photos go to your inbox.
For real estate agents
The home inspector wrote 'further evaluation by a chimney specialist'. What our Level 2 adds, and who receives it.
Property managers and HOAs
A twelve-month chimney plan across a portfolio, building by building, at $54 per fireplace for the yearly round.
Up to code repairs
What moves in an earthquake comes first: crowns, loose brick, prefab chase framing and pipe joints, then the smaller fixes.
How a prefab fireplace gets checked and fixed
The order we follow on a metal firebox and framed chase, from reading the rating plate to fitting the listed part.
Tell Us the Fireplace
Send the form with the address and what the fireplace is doing. If you can read the label inside the frame, include the maker and model; if not, we find it on the visit.
Parts Looked Up First
Once we know the model, we pull its installation manual and check which panels, doors and caps are listed for it, so the visit is planned around the right parts.
Label, Box, Flue, Roof
On site we read the rating plate, check the firebox and damper, run the flue and look at the chase top and cap, photographing each one.
Report and Written Quote
You receive the photos and a part-by-part report, plus a written quote for anything that needs replacing. Nothing is ordered until you approve it.
Listed Parts Installed
Approved parts are ordered for your model and fitted per the manual. We test the unit afterward and add the work to your file for the next visit.
Mention the maker and model if the label is readable.
Where the prefab fireplaces are
Our days start in Hawthorne and run through Inglewood, Compton and South Gate, where many houses and condos have a metal firebox. Type a city or ZIP to find its page.
Hawthorne
Home base for Wheeler, incorporated 1922
Owners live in just 27% of homes, and apartments lead the mix. Masonry or factory-built, every firebox starts with its data plate for us, and metal units get repaired to the maker's listing rather than by masonry habit.
Inglewood
Market Street, postwar flats and period streets
In Morningside Park and Fairview Heights, the interwar houses wear stucco or Spanish style, and a 32% slice of all homes is pre-1950. An original masonry box and a later metal insert are two jobs, so we name which one is in the wall first.
Compton
Rosecrans Avenue tracts and the Metro A Line stop
Tract streets are mostly small postwar stucco ranches, while 30% of homes reach back before 1950, the era of brick laid on site. Brick and a factory-built unit answer to different rules, so we pin down the system before ordering parts.
South Gate
Tweedy Boulevard blocks and the Hollydale streets
One brick chimney per postwar tract house is typical, often with steel inside, now decades old, and 47% of homes are pre-1950. Any insert or factory-built box added since gets measured against its own listing, separate from the masonry.
Further Out
136 more Wheeler city pages
Units We See on These Routes
Which kind is in your wall?
Around Hawthorne, most calls involve one of these three, and each is handled by its own rules.
Metal wood-burning box
Common in 1970s and 1980s tracts. Refractory panels, a damper and a metal flue in a framed chase, all listed as one unit.
Sealed gas unit
Typical in condos and newer townhomes. Glass front, a pilot and valve, and a vent through the wall or roof, serviced from the manual.
Older brick fireplace
Found on many prewar and postwar houses. Firebrick, a cast iron damper and a tile-lined stack, repaired as masonry.
Metal firebox, framed chase, and something is not right?
Tell us the address and what the unit is doing. We read the label on site, check it part by part, and quote any listed replacement in writing before ordering it.
(323) 524-5350Unsure of the maker? We find it on the visit.
Which Part Is the Problem?
Name, number and the symptom. Panel, damper, chase top or cap all count.
What Hawthorne owners ask about prefab fireplaces
Answers name the part and the rule behind it. Something missing? Ask through the contact page.